Products

Rat TNC(Tenascin C) ELISA Kit

ER1392 Catalogue No.
TNC ELISA Kit, Tenascin C ELISA Kit, Tenascin ELISA Kit, JI ELISA Kit, Hexabrachion ELISA Kit, Glioma-associated-extracellular matrix antigen ELISA Kit, GP 150-225 ELISA Kit, Neuronectin ELISA Kit, Myotendinous antigen ELISA Kit, Cytotactin ELISA Kit, GMEM ELISA Kit, HXB ELISA Kit, Tenascin J1 ELISA Kit, Cytotactin ELISA Kit, Glioma-associated-extracellular matrix antigen ELISA Kit, Hexabrachion ELISA Kit, hexabrachion ELISA Kit, tenascin ELISA Kit, HXBcytotactin ELISA Kit, TN-C ELISA Kit, TNGP ELISA Kit
Reactivity:
Rat
Range:
31.25-2000pg/ml
Sensitivity:
18.75pg/ml
Product Name
Rat TNC(Tenascin C) ELISA Kit
Catalogue No.
ER1392
Alias
TNC ELISA Kit, Tenascin C ELISA Kit, Tenascin ELISA Kit, JI ELISA Kit, Hexabrachion ELISA Kit, Glioma-associated-extracellular matrix antigen ELISA Kit, GP 150-225 ELISA Kit, Neuronectin ELISA Kit, Myotendinous antigen ELISA Kit, Cytotactin ELISA Kit, GMEM ELISA Kit, HXB ELISA Kit, Tenascin J1 ELISA Kit, Cytotactin ELISA Kit, Glioma-associated-extracellular matrix antigen ELISA Kit, Hexabrachion ELISA Kit, hexabrachion ELISA Kit, tenascin ELISA Kit, HXBcytotactin ELISA Kit, TN-C ELISA Kit, TNGP ELISA Kit
Detection Method
Sandwich ELISA, Double Antibody
Application
TNC ELISA Kit allows for the in vitro quantitative determination of TNC concentrations in serum, plasma, tissue homogenates and other biological fluids.
Size
96T
Range
31.25-2000pg/ml
Sensitivity
< 18.75pg/ml
Species
Rat
UniProt ID
B2LYI9
Standard curve
Storage
2-8 ℃ for 6 months
Recovery

Matrices listed below were spiked with certain level of TNC and the recovery rates were calculated by comparing the measured value to the expected amount of TNC in samples.

MatrixRecovery range(%)Average(%)
serum(n=5)91-10498
EDTA plasma(n=5)88-9592
heparin plasma(n=5)87-10597
Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TNC and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample1:21:41:8
serum(n=5)86-104%90-103%85-100%
EDTA plasma(n=5)85-101%82-97%90-101%
heparin plasma(n=5)84-100%84-100%82-96%
CV(%)
Intra-Assay: CV<8%
Inter-Assay: CV<10%
Note
For Research Use Only