Products

Mouse NFIL3(Nuclear Factor, Interleukin 3 Regulated) ELISA Kit

EM1229 Catalogue No.
NFIL3 ELISA Kit, E4BP4 ELISA Kit, IL3BP1 ELISA Kit, NF-IL3A ELISA Kit, E4BP4IL3BP1 ELISA Kit, Interleukin-3 promoter transcriptional activator ELISA Kit, Interleukin-3-binding protein 1 ELISA Kit, NF-IL3A ELISA Kit, NFIL3AE4 promoter-binding protein 4 ELISA Kit, nuclear factor interleukin 3 regulated protein ELISA Kit, nuclear factor interleukin-3-regulated protein ELISA Kit, nuclear factor ELISA Kit, interleukin 3 regulated ELISA Kit, Transcriptional activator NF-IL3A ELISA Kit
Reactivity:
Mouse
Range:
0.313-20ng/ml
Sensitivity:
0.188ng/ml
Product Name
Mouse NFIL3(Nuclear Factor, Interleukin 3 Regulated) ELISA Kit
Catalogue No.
EM1229
Alias
NFIL3 ELISA Kit, E4BP4 ELISA Kit, IL3BP1 ELISA Kit, NF-IL3A ELISA Kit, E4BP4IL3BP1 ELISA Kit, Interleukin-3 promoter transcriptional activator ELISA Kit, Interleukin-3-binding protein 1 ELISA Kit, NF-IL3A ELISA Kit, NFIL3AE4 promoter-binding protein 4 ELISA Kit, nuclear factor interleukin 3 regulated protein ELISA Kit, nuclear factor interleukin-3-regulated protein ELISA Kit, nuclear factor ELISA Kit, interleukin 3 regulated ELISA Kit, Transcriptional activator NF-IL3A ELISA Kit
Detection Method
Sandwich ELISA, Double Antibody
Application
NFIL3 ELISA Kit allows for the in vitro quantitative determination of NFIL3 concentrations in serum, plasma, tissue homogenates and other biological fluids.
Size
96T
Range
0.313-20ng/ml
Sensitivity
< 0.188ng/ml
Species
Mouse
UniProt ID
O08750
Standard curve
Storage
2-8 ℃ for 6 months
Recovery

Matrices listed below were spiked with certain level of NFIL3 and the recovery rates were calculated by comparing the measured value to the expected amount of NFIL3 in samples.

MatrixRecovery range(%)Average(%)
serum(n=5)86-9890
EDTA plasma(n=5)86-10598
heparin plasma(n=5)87-10498
Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of NFIL3 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample1:21:41:8
serum(n=5)87-102%95-103%92-102%
EDTA plasma(n=5)82-100%93-101%82-100%
heparin plasma(n=5)82-94%87-98%80-96%
CV(%)
Intra-Assay: CV<8%
Inter-Assay: CV<10%
Note
For Research Use Only