Products

Mouse GP4/CD36(Platelet Membrane Glycoprotein IV) ELISA Kit

EM1082 Catalogue No.
CD36 ELISA Kit, Collagen R ELISA Kit, FAT ELISA Kit, GPIIIb ELISA Kit, GPIV ELISA Kit, SCARB3 ELISA Kit, SR-B3 ELISA Kit, Thrombospondin R ELISA Kit, CD36 antigen ELISA Kit, CD36 molecule ELISA Kit, thrombospondin receptor ELISA Kit, FATCHDS7 ELISA Kit, Fatty acid translocase ELISA Kit, Glycoprotein IIIb ELISA Kit, GP3Bthrombospondin receptor ELISA Kit, GPIIIB ELISA Kit, Leukocyte differentiation antigen CD36 ELISA Kit, PAS IV ELISA Kit, PAS-4 ELISA Kit, Platelet collagen receptor ELISA Kit, platelet glycoprotein 4 ELISA Kit, Platelet glycoprotein IV ELISA Kit, scavenger receptor class B ELISA Kit, member 3 ELISA Kit, Thrombospondin receptor ELISA Kit
Reactivity:
Mouse
Range:
0.313-20ng/ml
Sensitivity:
0.188ng/ml
Product Name
Mouse GP4/CD36(Platelet Membrane Glycoprotein IV) ELISA Kit
Catalogue No.
EM1082
Alias
CD36 ELISA Kit, Collagen R ELISA Kit, FAT ELISA Kit, GPIIIb ELISA Kit, GPIV ELISA Kit, SCARB3 ELISA Kit, SR-B3 ELISA Kit, Thrombospondin R ELISA Kit, CD36 antigen ELISA Kit, CD36 molecule ELISA Kit, thrombospondin receptor ELISA Kit, FATCHDS7 ELISA Kit, Fatty acid translocase ELISA Kit, Glycoprotein IIIb ELISA Kit, GP3Bthrombospondin receptor ELISA Kit, GPIIIB ELISA Kit, Leukocyte differentiation antigen CD36 ELISA Kit, PAS IV ELISA Kit, PAS-4 ELISA Kit, Platelet collagen receptor ELISA Kit, platelet glycoprotein 4 ELISA Kit, Platelet glycoprotein IV ELISA Kit, scavenger receptor class B ELISA Kit, member 3 ELISA Kit, Thrombospondin receptor ELISA Kit
Detection Method
Sandwich ELISA, Double Antibody
Application
GP4/CD36 ELISA Kit allows for the in vitro quantitative determination of GP4/CD36 concentrations in serum, plasma, tissue homogenates and other biological fluids.
Size
96T
Range
0.313-20ng/ml
Sensitivity
< 0.188ng/ml
Species
Mouse
UniProt ID
Q08857
Standard curve
Storage
2-8 ℃ for 6 months
Recovery

Matrices listed below were spiked with certain level of GP4/CD36 and the recovery rates were calculated by comparing the measured value to the expected amount of GP4/CD36 in samples.

MatrixRecovery range(%)Average(%)
serum(n=5)92-10499
EDTA plasma(n=5)88-10397
heparin plasma(n=5)88-10495
Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GP4/CD36 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample1:21:41:8
serum(n=5)89-105%89-103%89-105%
EDTA plasma(n=5)88-100%89-101%82-92%
heparin plasma(n=5)84-96%81-99%86-99%
CV(%)
Intra-Assay: CV<8%
Inter-Assay: CV<10%
Note
For Research Use Only