Products

Mouse BAD(Bcl-2 Associated Death Promoter) ELISA Kit

EM0865 Catalogue No.
BAD ELISA Kit, BBC6 ELISA Kit, BCL2L8 ELISA Kit, BBC2 ELISA Kit, BBC6 ELISA Kit, bcl2 antagonist of cell death ELISA Kit, BCL2-antagonist of cell death protein ELISA Kit, BCL2-associated agonist of cell death ELISA Kit, Bcl-2-binding component 6 ELISA Kit, BCL2-binding component 6 ELISA Kit, BCL2-binding protein ELISA Kit, Bcl2-L-8 ELISA Kit, BCL2L8bcl2-L-8 ELISA Kit, Bcl-2-like protein 8 ELISA Kit, BCL-X ELISA Kit, BCL-2 binding protein ELISA Kit, Bcl-XL ELISA Kit, Bcl-2-associated death promoter ELISA Kit, Bcl-2-binding component 6 ELISA Kit, Bcl-xL ELISA Kit, Bcl-2-associated death promoter ELISA Kit
Reactivity:
Mouse
Range:
31.25-2000pg/ml
Sensitivity:
18.75pg/ml
Product Name
Mouse BAD(Bcl-2 Associated Death Promoter) ELISA Kit
Catalogue No.
EM0865
Alias
BAD ELISA Kit, BBC6 ELISA Kit, BCL2L8 ELISA Kit, BBC2 ELISA Kit, BBC6 ELISA Kit, bcl2 antagonist of cell death ELISA Kit, BCL2-antagonist of cell death protein ELISA Kit, BCL2-associated agonist of cell death ELISA Kit, Bcl-2-binding component 6 ELISA Kit, BCL2-binding component 6 ELISA Kit, BCL2-binding protein ELISA Kit, Bcl2-L-8 ELISA Kit, BCL2L8bcl2-L-8 ELISA Kit, Bcl-2-like protein 8 ELISA Kit, BCL-X ELISA Kit, BCL-2 binding protein ELISA Kit, Bcl-XL ELISA Kit, Bcl-2-associated death promoter ELISA Kit, Bcl-2-binding component 6 ELISA Kit, Bcl-xL ELISA Kit, Bcl-2-associated death promoter ELISA Kit
Detection Method
Sandwich ELISA, Double Antibody
Application
BAD ELISA Kit allows for the in vitro quantitative determination of BAD concentrations in serum, plasma, tissue homogenates and other biological fluids.
Size
96T
Range
31.25-2000pg/ml
Sensitivity
< 18.75pg/ml
Species
Mouse
UniProt ID
Q61337
Standard curve
Storage
2-8 ℃ for 6 months
Recovery

Matrices listed below were spiked with certain level of BAD and the recovery rates were calculated by comparing the measured value to the expected amount of BAD in samples.

MatrixRecovery range(%)Average(%)
serum(n=5)95-10097
EDTA plasma(n=5)86-10496
heparin plasma(n=5)88-10195
Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of BAD and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample1:21:41:8
serum(n=5)88-104%87-104%88-101%
EDTA plasma(n=5)82-88%83-99%83-98%
heparin plasma(n=5)83-100%82-100%87-96%
CV(%)
Intra-Assay: CV<8%
Inter-Assay: CV<10%
Note
For Research Use Only